Pressure Controls

  • Items 1-24 of 27. Page 1 of 2.
P100DA-1C Johnson Controls
Encapsulated Pressure Switch Manual Reset 410psi Cut-Out* switch opens on rise at 410psi requires manual reset.

Johnson Controls

P100DA-1C

078502828101

Manual Reset

High Pressure

Encapsulated

1/4 F Flare

410 Manual Reset

SPST

$76.32 EA
$146.77
55 In Stock
P100DA-81C Johnson Controls
Encapsulated Pressure Switch Manual Reset 630psi Cut Out switch opens on rise at 630psi requires manual reset. R410A

Johnson Controls

P100DA-81C

10662011084379

Manual Reset

High Pressure

Encapsulated

1/4 F Flare

630 Manual Reset

SPST

$64.52 EA
$124.07
31 In Stock
P70DA-1C Johnson Controls
Refrigeration High Pressure Control. Manual Reset. SPST Switch Opens On A Rise. Range 50-450 PSI. Rating 20A @ 120 17A @ 208/240. 36 Cap Tube With 1/4 Flare Nut.

Johnson Controls

P70DA-1C

Manual Reset

High Pressure

Capillary

1/4 F Flare

50-450 PSI

SPST

$180.17 EA
$346.49
15 In Stock
30GT660018 Carlyle
(Danfoss) Oil Pressure Safety- Retrofit Kit Replaces HK06UB006 HK06UC001 HK06UC011

Carlyle Compressor

30GT660018

00662442919366

Manual Reset

Oil Pressure

Capillary

1/4 F Flare

Fixed 6 PSID

SPDT

$333.44 EA
$629.13
14 In Stock
P145NCB-12C Johnson
Lube Oil Pressure Cutout Control, 120 Second Time Delay, 120/240 Vac, Manual Reset, 425 PSIG Maximum Bellows Pressure, 9 PSI Fixed Differential, 1/4" Male Flare Pressure Connection

Johnson Controls

P145NCB-12C

Manual Reset

Oil Pressure

Hose

1/4 M Flare

Fixed 9 PSID

SPST

$363.49 EA
$699.02
14 In Stock
P70MA-1C Johnson Controls
Dual Pressure Control. SPST. Opens Below low & Above High Press Settings. Range 20 -100 & 100-425 PSI. Low Dif. 6-50 PSI high Man. Reset. 36 Cap Tube With 1/4 Flare Nut. 20A @ 120 17A @ 208/240.

Johnson Controls

P70MA-1C

Manual Reset

Dual Pressure

Capillary

1/4 F Flare

20"-100 PSI / 100-500 PSI

SPST

$305.26 EA
$587.04
16 In Stock
P28AA-17C Johnson
Oil Safety 120 Sec 120/240 Vac * Lube Oil Safety Control. SPST Opens On A fall. Range 8-70 PSI. Diff 5 PSI. 120 Sec Delay. 120/240 Heater Circuit. Manual reset. 36 Cap Tube With 1/4 Flare Nut.10A @ 120V 5A @ 120V.For R1222500502

Johnson Controls

P28AA-17C

Manual Reset

Oil Pressure

Capillary

1/4 F Flare

8-70 PSID

SPST

$392.59 EA
$754.99
9 In Stock
FD113ZUK Emerson Alco 097456
Oil Pressure Safety Control. Range 4-65#Timing 20-150 Seconds. Manual Reset. 2 SPDT Switches Jumpered Together Can Be Set Up For 2 Circuits

Alco

FD113ZUK

Manual Reset

Oil Pressure

Capillary

1/4 F Flare

4-65PSID

SPDT

$320.31 EA
$604.36
15 In Stock
P28AA-1C Johnson Controls
Lube Oil Protection Contrl. SPST Opens On fall. Range 8-70PSI.Fixed Dif 5PSI.90 Sec time Delay. 120/240 Heater Circuit. Manualreset. 36 Cap Tube With 1/4 Flare Nut. 10A @ 120 5A @ 240.

Johnson Controls

P28AA-1C

Manual Reset

Oil Pressure

Capillary

1/4 F Flare

8-70 PSID

SPST

$392.59 EA
$754.99
6 In Stock
P545NCB-22C Johnson Controls
Electronic Lube Oil Control Comes with Sensor# P400AD-2C and Harness# WHA-P400-100C Opens at 12.75 PSI with 120 second delay. SPDT relay for alarm and liquid line solenoid. 120 or 240v. Replaces Copeland# 998-0105-01

Johnson Controls

P545NCB-22C

Manual Reset

Oil Pressure

Wire

3/4 M NPT

Open 12.75 Close 1.5

SPDT

$353.90 EA
$680.57
2 In Stock
P70DA-400C Johnson Manual Reset
high pressure control for R410a refrigerant. SPST switch opens on a rise. Range 200 to 610 PSI. 36 inch cap tube with 1/4 flare connection. HP rating 2 @ 120, 3 @240V. 24 Amps

Johnson Controls

P70DA-400C

Manual Reset

High Pressure

Capillary

1/4 F Flare

200-610 PSI

SPST

$179.37 EA
$344.95
3 In Stock
P145NCA-82C Johnson
Lube oil control for Carlyle * Lube oil pressure control. Replaces P45NCA-82 Carlyle HK06CA-500. 45 seconf delay. 120/240 VAC heater circuit. Manual Reset. Factory set at 6.5 PSI/ 1/4 male flare connection on bottom of control.

Johnson Controls

P145NCA-82C

01107850282903

Manual Reset

Oil Pressure

Hose

1/4 M Flare

Fixed 6.5 PSID

SPST

$335.17 EA
$644.56
2 In Stock
P45NAA-5C Johnson
Lube Oil Diff Pressure Control 120 SEC, 9 Psi Fixed, 24V Htr

Johnson Controls

P45NAA-5C

Manual Reset

Oil Pressure

Capillary

1/4 F Flare

7-60 PSID

SPST

$376.86 EA
$724.73
1 In Stock
P70MA-2C Johnson Controls
Dual Pressure Control. SPST Opens Below Low& Above High Press Setting. Range 20 TO100 PSI 100-425 PSI. Adjustable Dif Low 6-50Pshigh Man. Reset. For Ammonia Systems. 1/4 FPT connections. 20A @120V

Johnson Controls

P70MA-2C

Manual Reset

Dual Pressure

Capillary

1/4 F Flare

20"-100 PSI / 100-500 PSI

SPST

$592.44 EA
$1,139.31
2 In Stock
O16-261 Ranco
Low Presure Manual Reset * Manual reset low pressure control. 10 inches to 100 PSI. Fixed differential 10 PSI. SPDT switch breaks on a fall in pressure. 48 inch cap tube with flare nut.

Ranco

O16-261

662013922764

Manual Reset

Low Pressure

Capillary

1/4 F Flare

10"-100 PSI

SPDT

$182.82 EA
$348.23
1 In Stock
P70DA-2C Johnson
REF.PRESS.SW 50-450PSI AMMONIA * REFRIGERATION HIGH PRESSURE CONTROL. SPST SWITCH OPENS ON A RISE. RANGE 50 TO450 PSI. MANUAL RESET. RATING 20A @ 120V17A @ 208/240. 1/4 FPT CONNECTION.

Johnson Controls

P70DA-2C

Manual Reset

High Pressure

Ammonia

1/4 F NPT

50-450 PSI

SPST

$328.08 EA
$630.92
5 In Stock
O16-200 Ranco
High Pressure Control. SPDT. Range 150-450 PSI. Manual Reset Locks Out High. 48 Cap. Tube With 1/4 Flare Nut. 20A @ 120V 17A @ 240V.

Ranco

O16-200

662013922740

Manual Reset

High Pressure

Capillary

1/4 F Flare

150-450 PSI

SPDT

$166.73 EA
$317.58
3 In Stock
P28AA-2C Johnson
Oil Safety 60 Sec 120/240 Vac * Lube Oil Safety Control. SPST Opens On A fall. Range 8-70 PSI. Diff 5 PSI. 60 Sec delay. 120/240 Heat Circuit. Manual Reset. 36 Cap Tube With 1/4 Flare Nut.10A @ 120 5A @ 240V For R1222500502 Discontinued from vend

Johnson Controls

P28AA-2C

Manual Reset

Oil Pressure

Capillary

1/4 F Flare

8-70 PSID

SPST

$280.76 EA
$539.92
1 In Stock
060B210966 Danfoss Parts 060b210991
OEM by Danfoss Lube Oil Control for Carlyle compressors Danfoss type MP54 P529 2430 6 psi fixed 120sec time delay Manual reset. 1/4 Male Flare connections. Control marked type MP. Functional Replacement use PART# 060B200766 6 psi fixed differential

Carlyle Compressor

060B210966

Manual Reset

Oil Pressure

Hose

1/4 M Flare

Fixed 9 PSID

SPDT

$232.06 EA
$437.84
1 In Stock
P20BB-1C Johnson
Ref Switch 7-150PSI Mr on Lo * Refrigeration Pressure Switch SPST Opens on Fall. Range 7-125 PSI. Manual Reset. 16A @ 120V 8A @ 240V Used With R12 & R22Factory Set: Contacts Open @ 40 PSIg On Pressure Drop; Requires Manual Reset.

Johnson Controls

P20BB-1C

Manual Reset

Low Pressure

Capillary

1/4 Sweat

7-150 PSI

SPST

$91.62 EA
$176.19
2 In Stock
P29NC-2C Johnson
Oil Safety 60 Sec With Delay * Lube Oil Protection Control. SPST Opens On Fall. Range 20-100 PSI. Fixed Dif. 1-3 PSI. 60 Sec. Time Delay. 1/4 Male Flare. 750Va @ 120/240V.

Johnson Controls

P29NC-2C

Manual Reset

Oil Pressure

Hose

1/4 M Flare

20-100 PSID

SPST

$367.42 EA
$706.58
1 In Stock
P20DB-1C Johnson
Ref Switch 100-450PSI Manual * Refrigeration Pressure Switch SPST Opens on Rise. Range 100-425 PSI. Manual Reset 16A @ 120V 8A @ 240V Used With R12 & R22 Factory Set: Contacts Open @ 400 PSIg On pressure Increase; Requires Manual Reset

Johnson Controls

P20DB-1C

Manual Reset

High Pressure

Capillary

1/4 Sweat

100-425 PSI

SPST

$129.03 EA
$248.14
1 In Stock
P28AA-18C Johnson
Oil Safety 45 Sec 120/240 Vac * Lube Oil Safety Control. SPST Opens On A fall. Range 8-70 PSI. Diff 5 PSI. 45 Sec delay. 120/240V Heater Circuit. Manual Reset. 36 Cap Tube With 1/4 Flare Nut.10A @ 120 5A @ 240V.For R1222500502

Johnson Controls

P28AA-18C

Manual Reset

Oil Pressure

Capillary

1/4 F Flare

8-70 PSID

SPST

$391.98 EA
$753.80
2 In Stock
P545NCB-82C Johnson
Electronic Lube Oil Control Includes: P400-AD-1C Differential Pressure Switch and WHA-P400-100 Wiring Harness. Switch Opens at 7# psid +/- 1 psi Replaces COPELAND SENTRONIC.

Johnson Controls

P545NCB-82C

Manual Reset

Oil Pressure

Wire

3/4 M NPT

Open 7 Close 2

SPDT

$403.20 EA
$775.39
1 In Stock
  • Items 1-24 of 27. Page 1 of 2.